Back
The XF TP series consists of a thumper, a digital memory radar, an arc
reflection method coupler(filter) in a two piece truck mountable
configuration with a 125' or 200' cable reel system. All controls for
the unit are on the integrated radar control unit requiring no access
to the thumper/filter for operation. The control unit can be mounted in
the cab or a tool bin of a truck. The watertight all aluminum thumper/filter
unit is designed to be mountable in the bed of a truck or a tool bin. The
unit can operate from 120V AC of 12V DC (optional) .
Specifications
Thumper Specifications
|
XF16-
1280v.2TP
|
XF16-
2560v.4TP
|
XF25-
1563v.2TP
|
XF25-
3126v.4TP
|
XF28-
1960v.4TP
|
XF28-
3920v.4TP
|
XF32-
5120v.4TP
|
XF36-
6480v.4TP
|
XF36-
7614v.4TP
|
Voltage
Note: Voltage can be adjusted with knob.
|
0-8kV; 0-16kV
|
0-12.5kV; 0-25kV
|
0-14kV; 0-28kV
|
0-8kV; 0-16kV; 0-32kV
|
0-9kV; 0-18kV; 0-36kV
|
Thump Rate
|
Approx. every 15 Seconds
|
Energy
|
1280 Joules @ 8kV and 16kV
|
2560 Joules @ 8kV and 16kV
|
1563 Joules @ 12.5kV and 25kV
|
3126 Joules @ 12.5kV and 25kV
|
1960 Joules @ 14kV and 28kV
|
3920 Joules @ 14kV and 28kV
|
5120 Joules @ 8kV, 16kV and 32kV
|
6480 Joules @ 9kV, 18kV and 36kV
|
7614 Joules @ 9kV, 18kV and 36kV
|
Weather
|
Operation from -20° F (-29° C) to 110° F (43° C).
Unit & Controls sealed for all weather operation.
|
Controls
|
All controls are motorized and operated by toggle switches.
|
120V AC
|
Standard
|
12V DC External
|
Standard
|
Optional
|
240V AC
|
Optional
|
Weight
|
230 Lbs.
|
320 Lbs.
|
250 Lbs.
|
340 Lbs.
|
250 Lbs.
|
340 Lbs.
|
540 Lbs.
|
|
|
Leads
|
25’ Shielded HV Lead terminated in Male MC Connector and a 25’ #2 Ground Cable are standard to interface a Cable Reel System. XF16,XF25 and XF28 units come standard with RG-8U cable. XF32 and XF36 units come standard with X-ray cable.
125’ and 200’ Cable Reel Systems are available.
Cables from Thumper to Control/TDR 15’
|
HV Coupler/Filter
|
An inductive filter is used to minimize distortion and energy loss.
|
TDR
Specifications
|
v.2 Monochrome
|
v.4 Color
|
Auto Analyze
|
Automatically marks end of cable and fault location and gives distance.
|
Screen
|
3.5” (8.9cm) x 4.5” (11.4cm) LCD with 320x240 dot matrix – Backlight Visible in Bright Light
|
10.5" diagonal (243mm x 185.1mm) color TFT LCD – Backlight Visible in Sun Light
|
Environmental
|
Radar contained within the sealed case of the thumper allowing all weather operation. Operable from -25° F (-31° C) to 110° F (43° C).
|
Radar contained within the sealed case of the thumper allowing all weather operation. Operable from 20° F (-7° C) to 120° F (49° C).
|
Accuracy
|
0.5% of the range selected
|
Memory
|
Nine Memories available. Software is also available for downloading traces to a Laptop
|
Fifteen Memories available. Software is also available for downloading traces to a Laptop
|
Additional Features
|
|
3 phase display, Current Impulse Method (CIM) available as options
|